• head_banner

Products

  • AUX0025 Low Pass Passive Filter filter out clutter interference in the test line to ensure true test signal

    AUX0025 Low Pass Passive Filter filter out clutter interference in the test line to ensure true test signal

     

     

    Dual-channel multi-pole LRC passive filter has flat frequency response, extremely low insertion loss, and steep high-frequency filtering characteristics. The input interface supports XLR (XLR) and banana sockets.

    When testing electrical performance products such as PCBA and Class D power amplifiers, it can effectively filter out clutter interference in the test line to ensure true test signal.

  • AUX0028 Low Pass Passive Filter provide pre-processing signal to D-level amplifier

    AUX0028 Low Pass Passive Filter provide pre-processing signal to D-level amplifier

     

     

     

    AUX0028 is an eight-channel low-pass passive filter that can provide pre-processing signal to D-level amplifier. It has the characteristics of passband of 20Hz-20kHz, very low insertion loss and steep high-frequency filtering.

    In the testing of electrical performance products such as PCBA and

    Class D power amplifier, it can effectively filter out clutter interference

    in the test line to keep the fidelity of test signal.

  • MS588 Artificial Human Mouth provide a stable, wide frequency response, low distortion standard sound source for testing

    MS588 Artificial Human Mouth provide a stable, wide frequency response, low distortion standard sound source for testing

     

     

    The simulator mouth is a sound source used to accurately simulate the sound of the human mouth. It can be used to measure the frequency response, distortion and other acoustic parameters of transmission and communication products such as mobile phones, telephones, microphones, and microphones on Bluetooth speakers. It can provide a stable, wide frequency response, low distortion standard sound source for testing. This product fully complies with the requirements of relevant international standards such as IEEE269, 661 and ITU-TP51.

  • AD711S & AD318S Artificial Human Ear used to simulate pressure field human ear pickup for testing near-field electroacoustic products  such as headphones

    AD711S & AD318S Artificial Human Ear used to simulate pressure field human ear pickup for testing near-field electroacoustic products such as headphones

     

     

    According to different standards, the simulator ears are divided into two specifications: AD711S and AD318S, which are used to simulate pressure field human ear pickup and is an indispensable accessory for testing near-field electroacoustic products such as headphones.

    With an audio analyzer, it can be used to test various acoustic parameters of headphones, including frequency response, THD, sensitivity, abnormal sound and delay, etc.

  • AD360 Test Rotary Table used for the directivity test of the ENC noise reduction characteristics of speakers, loudspeaker box, microphones and earphones

    AD360 Test Rotary Table used for the directivity test of the ENC noise reduction characteristics of speakers, loudspeaker box, microphones and earphones

     

     

    AD360 is an electric integrated rotary table, which can control the rotation angle through the driver to realize the multi-angle directivity test of the product. The rotary table is built with a balanced force structure, which can carry tested products smoothly.

    It is specially used for the directivity test of the ENC noise reduction characteristics of speakers, loudspeaker box, microphones and earphones.

  • MIC-20 Free Field Measurement Microphone  test speakers, loudspeaker box and other products

    MIC-20 Free Field Measurement Microphone test speakers, loudspeaker box and other products

     

     

    It is a high-precision 1/2-inch free-field microphone, suitable for measurement in free-field without any change in sound. This microphone’s specification makes it ideal for sound pressure measurements in accordance with IEC61672 Class1. It can test speakers, loudspeaker box and other products.

  • KK Audio Test Software used to control its audio analyzer for acoustic testing

    KK Audio Test Software used to control its audio analyzer for acoustic testing

     

     

    KK audio test software is independently developed by Aupuxin Enterprise, which is used to control its audio analyzer for acoustic testing. After years of ongoing updating, it has been developed to version V3.1 .

    In order to meet the different types of test requirements in the market, KK has continuously added the latest test functions: open loop test, transfer function measurement, directivity measurement, waterfall diagram display, voice clarity score, etc.

  • SC200 sound proof box

    SC200 sound proof box

    When testing Bluetooth headsets, speakers, and speakers, it is used to simulate the anechoic chamber environment and isolate external Bluetooth radio frequency and noise signals.

    It can assist R&D institutions that do not have anechoic chamber conditions to conduct accurate acoustic testing. The box body is a stainless steel one-piece molded edge-sealed structure with excellent RF signal shielding. Sound-absorbing cotton and spiked cotton are implanted inside to effectively absorb the sound.

    It is a rare high-performance acoustic environment test box.

    The size of sound proof  box can be customized.

  • Headphone Audio Test Solution

    Headphone Audio Test Solution

    The audio test system supports 4-channel parallel and 8-channel alternating operation. The system is suitable for headphone testing and audio testing of other products.
    The system has the characteristics of high test efficiency and strong replaceability. The components adopt modular design, and customers can replace relevant fixtures according to their needs to adapt to the testing of different types of headphones.