DDC1203 DC Voltage Regulator Power Supply prevent test interruption caused by low voltage falling edge triggering

Everything you need to meet your testing needs

 

 

DDC1203 is a high performance, transient response DC source for peak current testing of digital wireless communication products. Excellent voltage transient response characteristics can prevent test interruption caused by low voltage falling edge triggering.


Main Performance

Product Tags

performance parameters

Specification
output range Voltage 0 ~ 15V
electric current 0 ~9V:0-5A / 0 ~ 15V : 0-3A
Ripple and Noise Voltage ( rms/pp ) 1 mV / 8 mV
Programmable precision Voltage 0.05 % + 10mV
electric current 5A: 0.16% + 5mA
programmable resolution Voltage 2.5mV
electric current 1.25 mA
Power Regulation Voltage ( CV ) 0.5mV _ _
Current ( CC ) 0.5mA _ _
Response time Instantaneous recovery time( for 1000% load change ) Within 100mV : < 40 uS ;Within 20mV : < 80 uS
Measurement characteristics Current 1.25mA
Readback accuracy Voltage 0.5mV
Readback resolution Current(cc) 0.5 mA
Load adjustment rate Transient recovery time for 1000% load change Within 100mv: <40uS; Within 20mv: <80uS
Measurement characteristics
Readback accuracy Voltage 0.05% + 3mV
electric current 5A: 0.2 % + 400uA ,5mA: 0.2%+1uA
Readback resolution Voltage 1mV
electric current 5A: 0.1mA , 5mA : 0.1uA
Load adjustment rate Voltage ( CV ) 0.01% + 2mV
Current ( CC ) 0.01% + 1mA
DVM (built-in digital voltmeter)
DC reading accuracy (23℃±5℃) +0.05%+3mV
Input voltage range 0-20VDC
Readback resolution 1mV
Other parameters
Absorption current 2A(Vout≤5V); 2A-0.1*(Vout-5)(Vout>5V)
Standard interface USB
Storage 5 Groups
Equipment Specifications
Operating temperature/humidity 0-40°C, <80%RH
Power Supply AC:100~240V,50/60HZ;150VA MAX
Dimensions 215mmX365mx95mm
weight 3.7kg